CRUSHING LOAD TABLES
LARGE DIAMETER PIPES
 
Hume Large Diameter Reinforced Concrete Pipes can be supplied and load tested in accordance to either AS 4058 - 1992 or MS 881 - 1991.
 

Nominal

Diameter

(mm)

 

Test Load kN/m To AS 4058 - 1992

Nominal

Length

(m)

 

Approximate

 Weight

Per pipe

(Tonne)

 
X Y Z

Proof

Load

Ultimate

Load

Proof

Load

Ultimate

Load

Proof

Load

Ultimate

Load

2100 70 105 105 158 140 210 2.50 7.00
2400 78 117 117 176 156 234 2.50 8.75
2700 86 129 129 194 172 258 2.50 10.50
3000 94 141 141 212 188 282 2.50 13.25
3300 102 153 153 230 204 306 2.25 14.80
3600 110 165 165 248 220 330 2.00 15.00
3900 118 177 177 266 236 354 1.50 14.00
4200 126 189 189 284 252 378 1.20 15.00
 

Nominal

Diameter

(mm)

 

Test Load kN/m To MS 881 - 1991

Nominal

Length

(m)

 

Approximate

 Weight

Per pipe

(Tonne)

 
L M H

Proof

Load

Ultimate

Load

Proof

Load

Ultimate

Load

Proof

Load

Ultimate

Load

 2100 96 120 146 183 184 230 2.50 7.00
 2400 108 135 165 207 210 263 2.50 8.75
 2700 124 155 186 233 235 294 2.50 10.50
 3000 135 169 207 259 260 326 2.50 13.25
 

Notes:

  1. Actual dimension may varies.
  2. Weights shown are approximate. Actual figures will vary with the densities of concrete aggregates and details of reinforcement.

Hume is able to manufacture customised pipes with increased cover to reinforcement and pipes made with special cements. If pipes required are not described here, please contact the nearest Hume office or factory.

 
 
Vertical Cast Pipe | Page 1 | Page 2 | Page 3 | Page 4 | Page 5 | Page 6 | Page 7 | Page 8 | Page 9 | Page 10 | Page 11
 
Top
HUME CONCRETE MARKETING SDN BHD (8411-T)
Level 2, Bangunan Pan Global,
No. 1A, Jalan Tandang,
P.O.Box 21, 46700
Petaling Jaya, Selangor.
Hot-line: (603) 7785 5282
Tel: (603) 7783 3068
Fax: (603) 7785 1823
E-mail: Adam Hussein (HIMB-PJ)